RCBO TPN
The latest & most innovative addition to Havells product range; RCBO which provides human safety by protecting against electrical shock, short circuit, fire hazards & indirect contacts.
It also provides protection to all types of electrical gadgets / installation from overload hazards.
Range :
- 30mA, 100mA, 300mA
Specification :
- IS 12640 Part 2, IEC 61009 - 2 - 2
Features :
- Electronic release (Voltage Dependent) having precise sensitivity to residual faults.
- Breaking Capacity 10 kA
- Detect Pulsating DC Faults - 'A' type
- Provision to accommodate TPN distribution boards
- Large terminals capacity i.e.35MM2 for cool running while in operation
- Enhanced immunity against nuisance tripping.
Tags:
Building Circuit Protection
,
RCBO
RCCB Higher Rating FP
The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical device cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called 'Leakage Current'.
Earth Leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth Leakage and its associated hazard can be prevented by residual current circuit breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).
Range :
- 16A to 63A
Execution :
- Four Pole (4P)
Specification :
- IEC 61008 - 1/IS 12640 - 1: 2000
Features :
- Simple and Robust operating mechanism.
- Rotary handle with ON/OFF indication
- Dual termination for Bus Bar as well as cable connection
- Advance Neutral.
- Test Button for regular inspection.
- Positive contact indication.
Four Pole - Changeover Switch
MCB Changeover switch finds wide & varied application in industries as well as in domestic sphere for use in low voltage distribution circuits, wherever continuity of supply is necessary, for switching to an alternate source of supply from main supply and vise-versa.
They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions, which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.
They are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions, which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.
Range :
- 25A & 40A
- bullet Four Pole (4P)
Specification:
- IS 13947 - 3 / IEC 60947 - 3
- bullet Compact construction
- bullet Double break contacts
- bullet Silver Cadmium Oxide contact tips
- bullet Shrouded terminals
- bullet Front operation with three stable positions I-O-II
- bullet Centre position off
- bullet Easy snap on DIN Rail mounting
- bullet Can be mounted with other products viz. MCB, ELCB, Isolator in Distribution Board
Four Pole 2 Module
They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time
Range:
- 40A-63A, 80A- 125A
- bullet Four Pole (2 Module)
- IS 13947 - 3 / IEC 60947 - 3
- bullet low Watt Loss
- bullet Longer Eletrical Life
- bullet Wide Range
- bullet Value for Money
- bullet Low power consumption,thus cost effective & energy saving
Tags:
Building Circuit Protection
,
Isolator
Isolator Four Pole
They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time
Range:
- 40A-63A, 80A- 125A
- bullet Four Pole (4P)
- IS 13947 - 3 / IEC 60947 - 3
- bullet low Watt Loss
- bullet Longer Eletrical Life
- bullet Wide Range
- bullet Value for Money
- bullet Low power consumption,thus cost effective & energy saving
Tags:
Building Circuit Protection
,
Isolator
Isolator TP
They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time
Range:
- 40A-63A, 80A- 125A
- bullet Three Pole (3P)
- IS 13947 - 3 / IEC 60947 - 3
- bullet low Watt Loss
- bullet Longer Eletrical Life
- bullet Wide Range
- bullet Value for Money
- bullet Low power consumption,thus cost effective & energy saving
Tags:
Building Circuit Protection
,
Isolator
Isolator DP
They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time
Range:
- 40A-63A, 80A- 125A
- bullet Double Pole (2P)
- IS 13947 - 3 / IEC 60947 - 3
- bullet low Watt Loss
- bullet Longer Eletrical Life
- bullet Wide Range
- bullet Value for Money
- bullet Low power consumption,thus cost effective & energy saving
Tags:
Building Circuit Protection
,
Isolator