Miniature Circuit Breaker

MCB High Undervol

18 Mar 2010
Electrical Distribution needs are continuously bevolving in residenti... 
More

Changeover Switch

Four Pole - Changeover Switch

18 Mar 2010
MCB Changeover switch finds wide & varied application in industri... 
More

Fans

Florence

10 Mar 2010
Features:1320 mm sweepFinish suiting modern intriors of house wood fu... 
More

Isolator

Four Pole 2 Module

18 Mar 2010
They are Switch Disconnectors with independent manual operation,capab... 
More

CFL

Higher Range 35 FU

10 Mar 2010
Lamp Wattage : 35W Cat Ref. No. : PHEFU*#35 Luman output (Lm) (L... 
More

Cables and Wires

XLPE Power - Control Cables

10 Mar 2010
Features:Highly compacted conductors to reduce AC losses which are du... 
More

RCBO TPN

The latest & most innovative addition to Havells product range; RCBO which provides human safety by protecting against electrical shock, short circuit, fire hazards & indirect contacts.It also provides protection to all types of electrical gadgets / installation

RCCB Higher Rating FP

The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical device cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This

Four Pole - Changeover Switch

MCB Changeover switch finds wide & varied application in industries as well as in domestic sphere for use in low voltage distribution circuits, wherever continuity of supply is necessary, for switching to an alternate source of supply from

Four Pole 2 Module

They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for

Isolator Four Pole

They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for

Isolator TP

They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for

Isolator DP

They are Switch Disconnectors with independent manual operation,capable of marketing,carrying and breaking currents under normal circuit conditions,which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for